Universal Electronic Ballast EBU 900
- Description
- Technical data
- Model
- Accessories
- Obtain an offer

The new series of universal digitized and μC-controlled ballasts replaces all electronic ballasts greater than 200 W
of LEJ for mixed gas, mercury and xenon short arc lamps.
Several lamp types are stored in the ballast and can be programmed by selecting the operating mode, output and
current at the device or an external interface before firing the lamp. A photo feedback input is available as an option. The series comes with numerous monitoring and safety functions.
Data Sheet:
Lamps | Type (selection) |
---|---|
Mercury from 350 W | HBO 350W HBO 500W, W/2 HBO 500W/A, W/B |
Input parameters | |
---|---|
Mains voltage | 100 ... 240 VAC, 50 ... 60 Hz |
Power input | max. 1.200 VA |
Output parameters | |
---|---|
Operation type | power controlled |
Power limitation | max 900 W |
Stability (8 hrs) | ≤ 2 x 10-2 |
Open-circuit voltage | max. 190 VDC |
Lamp voltage | max. 100 VDC |
Lamp current | max. 30 ADC |

Desktop device | |
---|---|
Dimensions (HxWxD) | 285 x 125 x 340 in mm |
Weight | 7,5 kg |
Luminaire housing | |
---|---|
Standard or customer-specific | on request |
Connecting Cable EBU-Ignitor | |
---|---|
Standard length 2 m | AK-EBU3030 |