Ignition Unit iu-0525
- Description
- Technical data
- Model
- Accessories
- Obtain an offer

The ignition unit type iu-0525 is used for igniting short-arc lamps with a maximum lamp current of 5.5 A, igniting voltage of 25 kV and open-circuit voltage of 55 V in combination with a suitable ballast.
The ignition unit must only be used together with a master device, which ensures that the operating conditions, the applicable safety requirements and the EMC requirements are complied with.
Data Sheet:
Input parameters | |
---|---|
Input voltage | 55 -65 V |
Input current | 10 mA |
Output parameters | |
---|---|
Ignition voltage | 25 - 30 kV |
Ignition time limited to | approx. 15 s |
Output current | max. 5,5 A, bei 30 °C |
Environmental conditions | |
---|---|
Operating temperature | 0 °C to 50 °C |
Storage temperature | - 40 °C to + 70 °C |
Conformity | |
---|---|
CE | |
RoHS |
Approvals | |
---|---|
UL/CSA (on request) |

Circuit board | |
---|---|
Dimensions (L x W x H) [without connections] |
100 mm x 46 mm x 36 mm |